If removing the cell is desired so that water may circulate without the cell, specialized plumbing would need to be added during installation of the cell. The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell. There are beads at the bottom of my pool, what does it mean? Need to, Your zip code will help us to provide you with the most up-to-date delivery information. Most common is the center pin.[9]. You are dealing with 240 Volts and electrical circuits. The purer the salt, the better the life and performance of the electrolytic cell. Error posting question. Buy in monthly payments with Affirm on orders over $50. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. Remove obstruction and/or clean cell. It may not display this or other websites correctly. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Salt should be added to the pool when necessary. JavaScript is disabled. In the event no such state or local requirement exists, the installer and maintainer must be a professional with sufficient experience in pool equipment installation and maintenance.". Dont use the little adaptor card between the cord plug and the circuit board. See Section 5, Operating Instructions section of the owner's manual. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Very happy with this controller. The Flow & Salinity Sensor is Jandy P/N R0452500. In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). We evaluated 6535 medical consults of intoxication cases involving prescription and over-the-counter drugs in 2001. $1,079.00. The PureLink DC Cord is Jandy P/N R0402800. These control pool and spa combinations sharing one set of equipment (Actuators included). See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. This is not a DIY product. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). You know what? See pages 13-14 in Jandy AquaPure Troubleshooting. We are sorry. When the tri-sensor fails the salinity will be incorrect or you will get a no-flow error. iAqualink 2.0 is Wi-Fi for the Aqualink system. Manufacturer SKU: 6967+. The prongs are sealed by O-rings and a compression plate held down by two screws. The only difference is the new part has a ground wire that was attached to the common ground.[15]. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. A great system, easy to install. The preferred salt is an evaporated, granulated, food quality, non-iodized salt. Sign up now. Salt Water Pool Generator Control Center Model# APUREM Retail is $1000 1 - Face Plate, Control Center, APUREM. Cell trisensor senses temperature, salinity and flow. Ensure there is no loss of pump prime or clogged strainer baskets. Zodiac Jandy iAquaLink 2.0 Wireless Network Pool Control Interface Sys. * Pricing, promotions and availability may vary by location and at lesliespool.com. We paired it with the APUREM. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. You can remove your cell for winter and install the dummy cell. eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . Plug flow/temp/salinity sensor into connector on power center printed circuit board. If you have a No-Flow error try resetting the circuit breaker and re-calibrating the tri-sensor before you consider replacing it. Please be aware that salt test strips have a large variance in readings (400 - 800 ppm). with the pool water. Check flow/temp/salinity sensor cable for damage. The water balance will be less threatened, because only pure chlorine is added to the water. Use Up and Down arrow keys to navigate search results. Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 . Jandy / Zodiac PLC1400 Replacement Cell Kit for AquaPure / PureLink 1400. Add To Cart. Some members add dielectric grease to the pins when they do their annual work on the filter and check the cell. The Jandy tri-sensor measures water flow, salinity, and water temperature. The production cycle time used for chlorine production (observationally) is 30 minutes. Had to replace our original, 14 year old system which developed a front board issue. No warranty when purchased online. Haha! Brand new! The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. Compact Chainsaw (Tool Only) New, JBL Live 300TWS True Wireless Earbuds Sweat and Water Resistent, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i7-1165G7 8GB RAM 512GB SSD, Lenovo ThinkPad X1 Carbon Gen 9 Intel Laptop, 14.0" IPS Low Blue Light, vPro, ONE PIECE TCG BOOSTER BOX ENGLISH Paramount War FACTORY SEALED NEW, Dyson V10 Animal + Cordless Vacuum Cleaner | Purple | Certified Refurbished, Legion 5 Pro 16" Gaming Laptop QHD 165Hz R9-6900HX 16GB RAM 1TB SSD RTX 3070 Ti, Men Cap Army Hat Cadet Castro Military Patrol Baseball Summer Camo Camouflage, adidas AEROREADY Designed to Move Feelready Sport Tee Men's, DJI Mavic Mini Intelligent Flight Battery-DJI Certified Refurbished, Sun Visor Hat Golf Tennis Beach Men Baseball Cap Adjustable Summer Plain Women, Intel Core i9-13900KF Unlocked Desktop Processor - 24 Cores (8P+16E) & 32 Thread, NEW WR60X10141 REFRIGERATOR FREEZER EVAPORATOR FAN MOTOR FITS GE HOTPOINT, PlayStation 5 Digital Edition God of War Ragnarok Bundle, Pokemon Dragonite VSTAR Deck Holder Tin Collection Factory Sealed Case (6 Units), Micron PRO 7450 PRO 15.36 TB Solid State Drive - 2.5" Internal - U.3 [PCI, Intel Core i5-12600K Unlocked Desktop Processor - 10 Cores (6P+4E) And 16 Thread, SanDisk 1TB Extreme Portable SSD V2 1050 MB/s USB-C USB 3.2 Gen 2 Solid State, AZZARO pour Homme Cologne 3.3 oz / 3.4 oz Tester (Rechargeable-Refillable), 6.5 x 9.25 Padded Bubble Mailer Color Logo, US Gold $20 Liberty Head Double Eagle - NGC MS62 - Random Date, Crocs Men's and Women's LiteRide Clogs | Slip On Shoes, Apple iPhone 11 Pro 64GB Unlocked Smartphone - Very Good, 6 x 8 Paperboard Mailjacket Envelope (No padding), Apple iPhone 12 Pro Max A2342 128GB Unlocked Good Condition, Scarlet and Violet Base Set Booster Box Pokemon TCG SEALED PREORDER SHIPS 3/31. Water conditioning salt pellets take longer to dissolve. It is being practiced by thousands of pool owners just like you. PLC700 (Cell Kit) 4.5 out of 5 stars 354 $ 1,098. Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. This aquapure is use with PLC700 or PLc1400 for salt system only. Check power. Reviewed in the United States on September 23, 2016, Reviewed in the United States on February 1, 2015, Reviewed in the United States on April 28, 2014. Jandy - Power Center Transformer for AquaLink RS and AquaPure. Please select a nearby store with available inventory to process your order. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. So the rating is 4 Stars. Brush the pool bottom and allow water to circulate for 24 hours to dissolve salt completely and mix evenly . 3 gpl is 3,000 ppm. Please try again. The PDA uses the pool's temperature sensor. Note that the center prong is on the cell where the power cord connects to the cell. It has 1 year manufacturer warranty. You are using an out of date browser. Is it true that a salt water chlorinator provides chlorine-free water? It's always important to test the salinity before adding salt to determine how much salt should be added. There was a problem adding this item to Cart. It is ok to startup the chlorinator when there is a little bromide in the pool. Note: The salinity or salt level should always be tested before salt is added to the pool. We have never winterized before. JANDY AQUAPURE PLASTIC CONTROL CENTER, MODELS 700 & 1400 JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 Categories POOL PARTS SPA PARTS CHEMICAL FEEDER CLEANERS FILTERS FILTER ELEMENTS FILTER VALVES FITTINGS & UNIONS HEATERS LIGHTS PILLOW PLEATCO PLUMBING VALVES PUMPS SKIMMERS SPA AIR BLOWERS SPA FITTINGS SPA PACK CONTROL COMPONENTS Had to call a pool guy. It is being practiced by thousands of pool owners just like you. Recommend strongly. Be the first to review this product! A separate communication will follow . This warranty applies only to products installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exists. Add salt as described in Section 4.7 of the owner's manual. Had to down load from another site. Search in reviews, Q&A. Manually shock the pool following the directions in Section 5.4.1 of the owner's manual, Shocking. You can usually see evidence of a leak when you know to look for it. Click the button below to add the JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 to your wish list. If you are switching from the 700 cell to the 1400 cell the JL1 jumper needs to be reconnected. Please consider. If corrosion appears in one year, it can be explained by incorrect water chemistry or bonding issue, not by the presence of salt alone. It uses 240V and 50/60hz Export. Pool guy installed quickly and it is working great. FREE delivery Feb 16 - 21 . Rely on its sturdy design and simple features to create your saltwater oasis. . No instructions contained w/unit. Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. Check for correct operation of the pump. Please consider. PLC1400 (Cell Kit), Dolphin Above Ground Robotic Pool Cleaners, Dolphin Residential Robotic Pool Cleaners, Solar Cover Blankets - Above Ground Pools, Utility Company Rebates for Pool Equipment, Kreepy Krauly Pool Cleaners Above Ground Pools, Kreepy Krauly Pool Cleaners Inground Ground Pools, Polaris Pool Cleaners - Above Ground Pools, Pentair Above Ground Pool and Spa Pool Heaters, Pentair Master Temp Inground Pool and Spa Heaters, Raypak Pool and Spa Heaters Gas and Propane, Hayward Commercial Thermoplastic Pump HCP Series, Hayward DEP 500 Series Pleated Element D.E. Earn at least $9 in pool perks for this item by joining Pool Perks. If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. While still pressing the test buttons press the Salinity key (C) on the front cover of the unit. No instructions contained w/unit. Is this unit a compatible replacement for an Aquapure 1400 control? Winterize your pool. ORP / External Control Interface 2. If the unit is not correctly installed you may get severe electrical shock or you may fry the system. Then the Aquapure system will be connected to your Aqualink system. (567 gm/24 Hr.). If still too low, Super Chlorinate with outside source. This difference in readings started about 1 week ago. Jandy AquaPure control center for Jandy AquaPure PLC1400 and PLC700 chlorine generator cells. Free shipping for many products! You need to determine the correct Revisio, Q: Perks can be redeemed online, in store or in the Leslies app. You can sometimes fix it by cleaning off the corrosion.[10]. Help others learn more about this product by uploading a video! Look at the label on the CPU for the firmware revision. Turn power to unit off and back on (Cycle Power). Add salt as described in Section 4.7 of the owner's manual. #1. Shop Online or at any of our 900+ retail stores! The remaining bromide in the pool will produce a white emulsion (chemical reaction). This is why changing this parameter is reserved for the pool professional. VERY GOOD PRODUCT, indeed, easy to install. Easy to install and use. The only hiccup we get, is an occasional communication error. This could be a defective automatic timer or pump switch or loose connection at the automatic timer or pump switch. It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Can this be used to replace an old Aquapure 1400 control box? Set Boost mode and allow to run for 24 hours. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. (Use sodium chloride only). Reviewed in the United States on June 20, 2014. The cell cannot be repaired even though the plates may have life left in them. Please make sure that you are posting in the form of a question. Check that ribbon cable is fully inserted into connector. If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. Recheck. NOTE: To clean the deposit (scale) on the electrolytic cell plates, see Section 6.3 of the owner's manual. The air temp went up. You can find instructions fore replacing and calibrating the tri-sensor in the AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual. Amazon.com: Zodiac R0403200 Control Box Cover Replacement for Zodiac AquaPure APURE1400 Plastic Control Center : Patio, Lawn & Garden . After installing began to flash code of 181 & 172. It includes aquapure control box only. Fits Zodiac Jandy AquaPure PureLink cell kit It is a weather resistant metal case and 4 relays Includes aquapure control box only Measures 6-inch diameter by 14-inch width by 9-1/2-inch height; 1 year manufacturer warranty Buy it with + + Total price: Add all three to Cart Show details $1,249.99 $69.56 When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. The salt under the effect of electrolysis, is transformed into sodium hypochlorite, a disinfectant. First thing to check is the cord. Adjust CHLORINE PRODUCTION to desired percentage. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. | IQ20-A. 3.0 to 3.5 gpl of salt is recommended for optimum water conditions. The system will beep when you push it and then at 5 seconds and again at 10 seconds. Turn on the chlorinator or increase the chlorine production percentage. Jandy has the Jandy SP3P Dummy Cell Cleaning Kit that includes everything you need to remove, clean, store, and/or bypass your Jandy AquaPure 3-Port Salt Cell. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. Stainless steel is better adapted to resist salt than Galvanised steel. It is usually located underneath your Aqualink cabinet. Regular Price: $212.61. We made the decision to go to a salt water pool system. In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. After 24 hours, verify correct salt reading. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. JavaScript is disabled. ORP / Freeze Control Unit 3 . 1 - Mounting Bracket, User Interface, APUREM. 624537. Rely on its sturdy design and simple features to create your saltwater oasis. Air, pool water, and SWG pool water. Sorry, we were unable to perform your search at this time. Integrates very well with Aqualink. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. Does the Freeze Protect mode use the reading from the tri-sensor or the pool temperature sensor? Amazon has encountered an error. Please note: This item is only available for in-store pickup and the selected store is out of stock. This is related to the serial com connections that are used. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. Either a short wait or a reboot resolve this. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE 352 8 offers from $1,209.92 Product Description This control box cover is designed to use with Zodiac AquaPure plastic control center model APURE700. If not, contact a pool professional. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. The system then reuses the salt and the process starts over again. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Wichita Falls, TX. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. Reviewed in the United States on December 6, 2014. Sorry - Air temperature sensor. Can I switch from bromide to salt water chlorination using the same water? Natural stone can be visually altered over time. For a better experience, please enable JavaScript in your browser before proceeding. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. An excellent system. Your panel uses the tri-sensor in the saltwater chlorine generator. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. You can recalibrate the unit if you are really sure about the actual salinity and you want the box to match your readings. Why You Should Only Work With A Qualified Professional. Rely on its sturdy design and simple features to create your saltwater oasis. Apple is not a participant or sponsor of this promotion. The arrow points to the water temperature sensor. If burnt connector contact authorized service representative. If so, yes it does., Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.Learn more how customers reviews work on Amazon. If the ladder is bonded properly to the rest of the pool equipment, corrosion will be minimal. Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Unit came with panel knocked out and the circuit board was bad. Plug flow/temp/salinity sensor into connector on power center printed circuit board. Thank you for your business! Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. good documentation. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. There were instructions included, but they were not as comprehensive as you would really need. See Section 6 of the owner's manual, User Maintenance Instructions. 2023 Zodiac Pool Systems LLC - All rights reserved. Brush down the affected walls and follow the directions in Section 5.4.1 of the owner's manual, Shocking. If chlorine output at the lowest setting consistently provides for excessive chlorine levels, decrease daily pump operation time as much as necessary. Jandy no longer supports parts for their older systems. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. I am concerned that this will affect Freeze Protect mode this winter. All other firmware uses program B on the trisensor inline module. 2 - Screws, Power Interface. The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. Jandy Aquapure Control Center. Filter, Hayward Star-Clear Cartridges C-250 thru C-1750, Hayward Swim Clear Large Capacity Cartridges, Pentair Purex Bottom Manifold Filter Grids, Pentair Replacement Cartridges QUAD Filters, Filter Backwash Valves, Diverter Valves, Check Valves, Hayward Navigator - PoolVac Cleaner Parts, Pool Control Systems and Automation Parts, Aquarite Cell Replacements - Above Ground, Hayward Aquarite Goldline Parts, Sensors, Boards, Jandy Zodiac Salt Cell PLC1400 Aquapure1400 PureLink Cell Kit 40K, Jandy PLC700 PureLink 7-Blade Salt Generator Cell Kit, Hayward Salt & Swim 3C Control Unit Only W3SAS-PRO, Hayward Salt & Swim 3C Replacement Salt Cell W3SAS-CELL, Pentair IntelliChlor Salt Generator Above Ground Pools IC15 EC-520888, SmartSalt Salt Chlorine Generator 25K 25,000 Gallons, Hayward AquaTrol RJ Salt Chlorine Generator W3AQ-TROL-RJ, Pentair Intellichlor IC60 Salt Water System 521105 and 520556. >PoolAndSpaPartsDepot.com is Open for Business! The LCD should read 2.8 gpl*. Not reliable at all and have had problems starting about 1 month after installation. Add salt to pool, 3.0 gpl to 3.5 gpl. Works like a champ. However, if you have any doubts, do not try this!!! In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved.